Device module wiring diagram
Wiring instructions:
① Line is setThe line is the Trident grounding wire of equipment power supply;
②[1.5m2 yellow-green] wire is the grounding wire between the equipment module and the protective ground (the internal common ground)
③ [1.5m2 yellow green] line is the grounding wire between equipment and protective ground
④ [1.5m2 Yellow green] line is the detection line between equipment and equipment module
Description of open circuit alarm:
① If the line is disconnected, the buzzer will not alarm if the line is not disconnected;
① If the line is not disconnected, ② the line is disconnected and the buzzer does not alarm;
①The line is disconnected, ②The line is disconnected, the buzzer will alarm;
③Line/④Line If any line is disconnected, the buzzer will alarm.
Wiring diagram of table cushion module
Wiring Description:
①[1.0m2 green] wire is the ground wire between the pad module and the electrostatic ground (the internal ground is common)
②[1.0m2green] line is the grounding wire (1M) between the pad and the electrostatic ground
③[1.0m2green] line is the detection line between table mat and table mat module
Description of open circuit alarm:
①Line disconnection alarm status:
Situation 1: The table mat is placed on a conductive table, and the conductive table is not grounded, ① the line is disconnected and the buzzer will alarm
Situation 2: The table mat is placed on a conductive table, and the conductive table is grounded. ① The buzzer does not alarm when the wire is disconnected
Situation 3: The table mat is placed on a non-conductive table, and the line is disconnected and the buzzer will alarm
②line/③line disconnection, buzzer alarm
Wiring diagram of wrist strap module
① Line is setThe line is the Trident grounding wire of equipment power supply;
②[1.5m2 yellow-green] wire is the grounding wire between the equipment module and the protective ground (the internal common ground)
③ [1.5m2 yellow green] line is the grounding wire between equipment and protective ground
④ [1.5m2 Yellow green] line is the detection line between equipment and equipment module
Description of open circuit alarm:
① If the line is disconnected, the buzzer will not alarm if the line is not disconnected;
① If the line is not disconnected, ② the line is disconnected and the buzzer does not alarm;
①The line is disconnected, ②The line is disconnected, the buzzer will alarm;
③Line/④Line If any line is disconnected, the buzzer will alarm.
Wiring diagram of table cushion module
①[1.0m2 green] wire is the ground wire between the pad module and the electrostatic ground (the internal ground is common)
②[1.0m2green] line is the grounding wire (1M) between the pad and the electrostatic ground
③[1.0m2green] line is the detection line between table mat and table mat module
Description of open circuit alarm:
①Line disconnection alarm status:
Situation 1: The table mat is placed on a conductive table, and the conductive table is not grounded, ① the line is disconnected and the buzzer will alarm
Situation 2: The table mat is placed on a conductive table, and the conductive table is grounded. ① The buzzer does not alarm when the wire is disconnected
Situation 3: The table mat is placed on a non-conductive table, and the line is disconnected and the buzzer will alarm
②line/③line disconnection, buzzer alarm
Wiring diagram of wrist strap module
Wiring Description:
①/②[1.0m green] wire is the grounding wire between the wrist strap module and the electrostatic ground
③[8 Pin flat] line is the connection line between the wristband module and the wristband socket
Description of open circuit alarm:
①/②The main ground or detection ground is disconnected, and the buzzer will alarm
③The connection line is broken and the buzzer will alarm
Equipment, table mat. Schematic diagram of mixed wiring of human body module
①/②[1.0m green] wire is the grounding wire between the wrist strap module and the electrostatic ground
③[8 Pin flat] line is the connection line between the wristband module and the wristband socket
Description of open circuit alarm:
①/②The main ground or detection ground is disconnected, and the buzzer will alarm
③The connection line is broken and the buzzer will alarm
Equipment, table mat. Schematic diagram of mixed wiring of human body module
Wiring Description:
①The wire is the three-prong ground wire of the equipment power supply;
②The [1.0m2 green] line is the grounding wire between the pad, the wrist strap module and the electrostatic ground (the internal ground is common)
③[1.0m2green] line is the detection line between the wrist strap module and the electrostatic ground
④[1.5m2 yellow-green] wire is the grounding wire between the equipment module and the protective ground
⑤[1.5m2 yellow-green] wire is the grounding wire between the equipment and the protective ground
⑥[1.5m2 yellow-green] line is the detection line between equipment and equipment module
⑦[1.0m2green] line is the grounding wire between the pad and the electrostatic ground (1M)
⑧[1.0m2green] line is the detection line between the table mat and the table mat module
⑨[8 Pin flat] line is the connection line between the wristband module and the wristband socket
①The wire is the three-prong ground wire of the equipment power supply;
②The [1.0m2 green] line is the grounding wire between the pad, the wrist strap module and the electrostatic ground (the internal ground is common)
③[1.0m2green] line is the detection line between the wrist strap module and the electrostatic ground
④[1.5m2 yellow-green] wire is the grounding wire between the equipment module and the protective ground
⑤[1.5m2 yellow-green] wire is the grounding wire between the equipment and the protective ground
⑥[1.5m2 yellow-green] line is the detection line between equipment and equipment module
⑦[1.0m2green] line is the grounding wire between the pad and the electrostatic ground (1M)
⑧[1.0m2green] line is the detection line between the table mat and the table mat module
⑨[8 Pin flat] line is the connection line between the wristband module and the wristband socket